Rust Grip 15,000 Hour Salt Spray Test-ASTM B117
74 Kent Street
Brooklyn, New York 11222
January 11, 2011
Superior Products International II, Inc.
10835 W. 78th Street
Shawnee, KS 66214
Att: Mr. Craig R. Smith
Technical Director
Re: DL–15881C
OBJECTIVE
To test a coating for compliance to the salt spray requirements as outlined in the Florida Department of Transportation specification.
PRODUCT TESTED
Coated panels were submitted by Superior Products II, Inc. and identified as:
Rust Grip NS 1, 6-mils through Rust Grip NS 3, 6-mils
TEST PROCEDURE
The coated panels were exposed in a Salt Fog Chamber maintained in accordance with ASTM B 117, for 15,000 hours. The panels were evaluated periodically for overall blistering in accordance with ASTM D 714 and rust staining in accordance with ASTM D 610.
TEST RESULTS
ASTM D 714, Degree of Blistering
Blister Size Frequency of Occurrence
10 – None F – Few
8 – Pinpoint size M – Medium
6 – 1/16-inch diameter approx. MD – Medium Dense
4 – 1/8-inch diameter approx. D – Dense
2 – ¼-inch diameter approx.
TEST RESULTS (cont.)
ASTM D 610, Degree of Rusting
Rust Grade Description
10 No rusting
9 Minute rusting, less than 0.03% of surface area
8 Few isolated areas, less than 0.1% of surface area
6 Extensive rust areas, less than 1% of surface area
4 Rusting to the extent of 10% of surface area
2 Approximately 33% of surface rusted
0 Approximately 100% of surface rusted
APPENDIX
TEST RESULTS
ASTM B 117 SALT SPRAY (FOG) CORROSION RESISTANCE
The three coated panels of Rust Grip NS, 6-mils exhibit the following:
Blistering Rust Staining
15,000 Hours Exposure 10 10
DL Labs, Inc.
Mario Lazaro, Jr.
Assistant Technical Director
Have Any Questions?
Call us at 917-836-7816 for more information about our products or services
Monday - Friday
9:00AM - 5:00PM